Checking the ground terminal
- Ignition off
- Disconnect central electronic module (CEM) connector D.
Check central electronic module (CEM) connector D. Check for contact resistance and oxidation. Check for damage carefully.
Check the ground lead between central electronic module (CEM) terminal #D6 (#6) and the ground terminal. Check for an open-circuit. Check for loose connections. Check for contact resistance and oxidation. With the ignition on, the drop in voltage between the ground connection for the central electronic module (CEM) and the ground terminal must not be greater than 0.5 V.
Remedy as necessary.
Other information
- For further information about the fuses and relays, see the appropriate Wiring Diagram
- See Connecting the breakout box
- See Signal specification
- See Location of components
- See Checking wiring and terminals
Was a fault detected?
- YES
Refer to Verification
- NO
Refer to Checking the battery