Modular Fuel Sender Assembly: Installation
- Install new lip seal on modular fuel sender assembly. Always use a new lip seal when servicing modular fuel sender unit. Lightly lubricate the inside diameter of the lip seal with engine oil. Lip seal should be carefully positioned over the float arm assembly, moved up over the reservoir and half way up the guide posts.
- Install modular fuel sender assembly into tank. Seat lip seal into tank opening.
- Align arrow on top of the fuel sender cover to arrow on the fuel tank.
- Slowly apply pressure to the top of the spring loaded sender until the lip seal is flush between the fuel tank and the fuel sender cover.
- Attach locking nut. Install fuel tank.
NOTE:
Ensure that the lip seal provides a snug seal between the modular unit and the fuel tank.