Power Windows Inoperative - Express Down Function
Power Windows Inoperative - Express Down Function
| Step | Action | Yes | No |
|---|---|---|---|
| Schematic Reference: Power Window Schematics DEFINITION: This diagnostic procedure should be used to diagnosis a failure of the express down power window feature. |
|||
| 1 | Did you perform the Power Door Systems Diagnostic System Check? | Go to Step 2 | Go to Diagnostic System Check - Door Systems |
| 2 |
|
Go to TESTING FOR INTERMITTENT AND POOR CONNECTIONS | Go to Step 3 |
| 3 | Inspect for poor connections at the harness connector of the power window master switch. Refer to TESTING FOR INTERMITTENT AND POOR CONNECTIONS
and CONNECTOR REPAIRS
. Did you find and correct the condition? |
Go to Step 5 | Go to Step 4 |
| 4 | Replace the power window master switch. Refer to Power Window Switch Replacement . Did you complete the repair? |
Go to Step 5 | - |
| 5 | Operate the system in order to verify the repair. Did you correct the condition? |
System OK | Go to Step 2 |