Power Mirror Motor Test
Access power mirror motor harness connector. See POWER MIRROR ASSEMBLY under REMOVAL & INSTALLATION. Disconnect power mirror motor harness connector. Using 12-volt power source, connect positive and negative leads to indicated motor terminals. See POWER MIRROR MOTOR TEST table. See Fig 1 . If motor fails any test, replace power mirror assembly.
POWER MIRROR MOTOR TEST
| Apply 12 Volts To Terminal No. | Ground Terminal No. | Mirror Operation |
|---|---|---|
| 3 | 2 | Up |
| 2 | 3 | Down |
| 1 | 2 | Left |
| 2 | 1 | Right |