Installation Procedure
- If the sensor is being reused, apply thread sealant GM P/N 12345382 (Canadian P/N 10953489) or equivalent, to sensor threads.
- Install the ECT sensor.
Tighten: Tighten the engine coolant temperature sensor to 23 N.m (17 lb ft).
- Connect the ECT sensor harness connector. Push in the connector until a click is heard, then pull back to confirm a positive engagement.
- Fill engine coolant to proper level. Refer to Draining and Filling Cooling System (Static Fill) or Draining and Filling Cooling System (GE 47716 Fill) .
IMPORTANT:
Tap out sensor mounting hole in engine head to remove any thread sealant residue. Clean any sealant residue from old sensor if the sensor is going to be reused.
NOTE:
Refer to Component Fastener Tightening Notice
.