LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Chevrolet >> 2007 >> Impala V6-3.5L >> Repair and Diagnosis >> Engine, Cooling and Exhaust >> Engine >> Timing Components >> Variable Valve Timing >> Variable Valve Timing Actuator >> Service and Repair
July 1: So it begins. Don't worry, this is not in the correct legal jurisdiction!

Variable Valve Timing Actuator: Service and Repair



Camshaft Position Actuator Magnet Replacement

Removal Procedure




1. Remove the intake manifold cover.
2. Disconnect the camshaft position actuator magnet electrical connector (2).




3. Remove the camshaft position actuator magnet bolts.
4. Remove the camshaft position actuator magnet and O-ring seal.

Installation Procedure




1. Install the camshaft position actuator magnet O-ring seal and magnet.
Notice: Refer to Fastener Notice.

2. Install the camshaft position actuator magnet bolts.

Tighten the bolts to 10 N.m (89 lb in).




3. Connect the camshaft position actuator magnet electrical connector (2).
4. Install the intake manifold cover.