Power Door Lock Test 4A - Liftgate Switch MUX Circuit Short To Ground
NOTE:
Perform POWER DOOR LOCK TEST 1B
before proceeding with this test. For connector terminal ID, see CONNECTOR IDENTIFICATION
and WIRING DIAGRAMS
. Perform TEST VER-1A - VERIFICATION PROCEDURE
after each repair.
CAUTION:
Always turn ignition switch to OFF position prior to disconnecting or connecting any module connector.
- Clear trouble codes as needed. See DIAGNOSTIC PROCEDURE . Turn ignition on. Wait 15 seconds. Using scan tool, read body control computer trouble codes (fault messages). If scan tool displays LIFTGATE DOOR MUX CKT SHORT TO GND, go to next step. If scan tool does not display LIFTGATE DOOR MUX CKT SHORT TO GND, system is currently operating correctly. Problem may be intermittent.
- Disconnect Body Control Module (BCM) connector "B". BCM is located with junction block under driver's side instrument panel. See Figure in CHIME TEST 2A. Using scan tool in ohmmeter mode, measure resistance at terminal No. 44 (White/Red wire) on connector "B". If resistance is 100 ohms or greater, replace BCM. If resistance is less than 100 ohms, repair White/Red wire for short to ground.