Test 152A - Door Lock Switch (Unlock) Output Circuit
NOTE:
Perform TEST 141A
before proceeding with this test. For connector terminal ID, see CONNECTOR IDENTIFICATION
. For wiring schematics, see WIRING DIAGRAMS
in this article. Perform TEST VER-3A - VERIFICATION PROCEDURE
after each repair.
CAUTION:
Always turn ignition off prior to disconnecting any module connector.
Turn ignition switch to ON position. Using scan tool, read door lock switch voltage. While monitoring scan tool, depress and hold door lock switch in UNLOCK position. If voltage is 4.5 volts or less, go to TEST 90A . If voltage is more than 4.5 volts, replace body control module.