IOD Wake Up Open - PLG
NOTE:
After making any repairs, perform BODY VERIFICATION TEST under VERIFICATION TESTS.
- Using scan tool, erase DTCs. Turn ignition off. Wait a minimum of 10 seconds. Turn ignition on. Wait another minimum of 10 seconds. Recheck for DTCs. If IOD WAKE UP OPEN - PLG resets, go to next step. If IOD WAKE UP OPEN - PLG does not reset, system is operating properly at this time. Check for intermittent poor connections or faulty circuits.
- Turn ignition off. Locate and disconnect Body Control Module (BCM) connector C2. See COMPONENT LOCATIONS . See Figure. Using DVOM, measure voltage between ground and BCM connector C2 terminal No. 17 (Violet/Yellow wire). If voltage is 10 volts or less, go to next step. If voltage is greater than 10 volts, replace BCM. See BODY CONTROL MODULE under REMOVAL & INSTALLATION.
- Disconnect Power Liftgate Module (PLGM) connector C1. See Figure. To access connector, left rear trim will need to be removed. See POWER LIFTGATE MODULE under REMOVAL & INSTALLATION. Using DVOM, measure resistance of Violet/Yellow wire between BCM connector C2 terminal No. 17 and PLGM connector C2 terminals No. 19. If resistance is 5 ohms or less, go to next step. If resistance is greater than 5 ohms, repair open in Violet/Yellow wire.
- Using DVOM, measure resistance between ground and BCM connector C2 terminal No. 17 (Violet/Yellow wire). If resistance is greater than 5 ohms, replace PLGM. If resistance is 5 ohms or less, repair short to ground in Violet/Yellow wire.