Non-Deployed Module
When removing an airbag for any reason other than DEPLOYMENT.
- Disconnect and isolate the battery negative cable.
- Wait two minutes for the system reserve capacitor to discharge before servicing any airbag components.
- Remove instrument panel top cover. Refer to INSTRUMENT CLUSTER .
- Remove three screws to glove box door and remove door from instrument panel.
- Remove three passenger airbag cover screws attaching cover to top of instrument panel. See Fig 1.
- Remove two passenger airbag cover screws attaching cover to front lower instrument panel.
- Remove three airbag attaching nuts from the support structure.
- Lift the airbag up until the wire connector is visible and disconnect the connector.