A/C Switch Signal
Connect system checker harness between ECU and connector. Start engine. Turn blower switch and A/C switches ON. Ensure compressor and condenser cooling fan are working. Connect voltmeter positive probe to terminal B8 (Blue/Red wire) and negative probe to terminal A18 (Black/Red wire). Voltage should be 0-3 volts. If not, check for open circuit in Blue/Red wire between A/C diode connector and ECU.
NOTE:
Voltage should be more than 9 volts if compressor or condenser cooling fan stops when power is cut-off by pressure switch or thermostat.