LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Honda >> 2014 >> Accord Plug-In >> Repair and Diagnosis (Single Page) >> Hybrid/Electric Powertrain >> Testing and Diagnosis >> Electric Powertrain System / Traction Motor System - Advanced Diagnostics (Hybrid) (P1D92 - U1206E) >> DTC Advanced Diagnostics >> DTC U0311: Traction Motor Control Module Program Version Mismatch (123)
April 5, 2026: LEMON Manuals is launched! Read the announcement.

DTC U0311: Traction Motor Control Module Program Version Mismatch (123)

General Description 

GHH263564Courtesy of HONDA, U.S.A., INC.

The motor control processor and the generator control processor software which are in the motor control module (traction) can be updated by software rewriting device connected via the F-CAN lines. When both processors need to be updated but either processor fails rewriting, the indicator comes on and stores a DTC. Each processor stores a program version information, and compare their versions each other by transmitting/receiving via the internal serial communication. If the motor control processor judges that its own software version is old, a malfunction is detected and a DTC is stored.

Monitor Execution, Sequence, Duration, DTC Type, OBD Status 

Execution Continuous
Sequence None
Duration 1 second or more
DTC Type One drive cycle, MIL on, POWER SYSTEM indicator on
OBD Status PASSED/FAILED/NOT COMPLETED (STILL TESTING)

Enable Conditions 

Condition  
Vehicle ON mode

Malfunction Threshold 

The motor control processor judges that its own software version is old for at least 1 second.

Possible Cause 

NOTE:  The causes shown may not be a complete list of all potential problems, and it is possible that there may be other causes.

Diagnosis Details 

Conditions for setting the DTC 

When a malfunction is detected, the MIL comes on and a Pending DTC, a Confirmed DTC, and the freeze data are stored in the motor control module (traction) memory.

Conditions for clearing the DTC 