Immobilizer-Keyless Control Unit Input Test
NOTE: SRS components are located in this area. Review the SRS component locations - Refer to: SRS Component Location Index ('12: Natural Gas models) , SRS Component Location Index ('12: except Natural Gas models) , SRS Component Location Index ('13-'15) , and precautions and procedures - Refer to: SRS Precautions and Procedures ('12) , SRS Precautions and Procedures ('13-'15) before doing repairs or servicing.
1. Turn the ignition switch to LOCK (0)
2. Disconnect the immobilizer-keyless control unit 7P connector.
3. Inspect the connector and socket terminals to be sure they are all making good contact.
- If the terminals are bent, loose, or corroded, repair them as necessary, and recheck the system.
- If the terminals are OK, go to step 4.
4. With the connector still disconnected, do the following input tests:
- If any test indicates a problem, find and correct the cause, then recheck the system.
- If all the input tests prove OK, go to step 5.
Cavity Wire Terminal name Test condition Test: Desired result Possible cause if desired result is not obtained 2 LT GRN S-NET Jump the SCS line with the HDS, disconnect ECM/PCM connector A (49P) - Refer to: How to Troubleshoot the Fuel and Emissions Systems (K24Z7) , How to Troubleshoot the Fuel and Emissions Systems (R18Z1) , How to Troubleshoot the A/T System (A/T) , How to Troubleshoot the Fuel and Emissions Systems (R18A9) , How to Troubleshoot the CVT System (CVT) ('14-'15) Measure the voltage to ground: There should be about 5 V. - An open or high resistance in the wire
- A short to ground in the wire
Check for continuity between the terminal and ECM/PCM connector A (49P) terminal No. 17: There should be continuity. An open or high resistance in the wire Disconnect the battery negative terminal Measure the resistance between the terminal and body ground: There should be more than 50 kΩ. - Faulty under-dash fuse/relay box
- Poor ground (G101)
- An open or high resistance in the ground wire
5. Reconnect the connector to the immobilizer-keyless control unit, do the following input tests:
- If any test indicates a problem, find and correct the cause, then recheck the system.
- If all the input tests prove OK, replace the immobilizer-keyless control unit - Refer to: Immobilizer-Keyless Control Unit Removal and Installation
, Immobilizer-Keyless Control Unit Registration
.
NOTE: After replacing the immobilizer-keyless control unit, do the immobilizer key registration .
Cavity Wire Terminal name Test condition Test: Desired result Possible cause if desired result is not obtained 7 WHT +B_BACK_UP Under all conditions Measure the voltage to ground: There should be battery voltage. - Blown No. A29 (10 A) fuse in the under-hood fuse/relay box
- An open or high resistance in the wire
6 YEL IG1_FUEL_PUMP Ignition switch ON (II) Measure the voltage to ground: There should be battery voltage. - Blown No. B4 (15 A) fuse in the under-dash fuse/relay box
- An open or high resistance in the wire
1 BLK LG In all ignition switch positions Measure the voltage to ground: There should be less than 0.2 V. - Poor ground (G101)
- An open or high resistance in the ground wire
3 LT BLU K_LINE Under all conditions Measure the voltage to ground: There should be pulse voltage (digital signal). - Faulty control unit on the K-LINE
- Short to ground in the K-LINE wire