Keyless/Power Door Locks/Security System Symptom Troubleshooting - Security alarm system will not arm: Inspection
HOOD_SW, GND Circuit Inspection
Test Procedure
- Preparation
- -
Hood latch switch connector (2P): disconnected
- -
Relay control module connector C (18P): disconnected
- -
- Procedure
- -
Perform the inspection according to the following chart.
- -
| (Disconnected)Hood latch switch connector (2P) female terminals | (Disconnected)Relay control module connector C (18P) female terminals | ||||
| IG Mode |
|
|
Normal Conditions | ||
| HOOD_SW open wire inspection | OFF | There is less than 1 Ohm | |||
| GND open wire inspection | OFF | There is less than 1 Ohm | |||
| HOOD_SW shorted to ground inspection | OFF | There is more than 1 MOhm |
Results
- If abnormal, there is a problem in the circuit.
FL_DOOR_SW, GND Open Wire Inspection
Test Procedure
- Preparation
- -
Driver's door latch connector (10P): disconnected
- -
Body control module connector B (66P): disconnected
- -
- Procedure
- -
Perform the inspection according to the following chart.
- -
| (Disconnected) Driver's door latch connector (10P) female terminals | (Disconnected)Body control module connector B (66P) female terminals | ||||
| IG Mode |
|
|
Normal Conditions | ||
| FL_DOOR_SW open wire inspection | OFF | There is less than 1 Ohm | |||
| GND open wire inspection | OFF | There is less than 1 Ohm | |||
Results
- If abnormal, there is a problem in the circuit.
DR_SILCON_UNLOCK, GND Circuit Inspection
Test Procedure
- Preparation
- -
Driver's door latch connector (10P): disconnected
- -
Power window master switch 37P connector: disconnected
- -
- Procedure
- -
Perform the inspection according to the following chart.
- -
| (Disconnected) Driver's door latch connector (10P) female terminals | (Disconnected)Power window master switch 37P connector female terminals | ||||
| IG Mode |
|
|
Normal Conditions | ||
| DR_SILCON_UNLOCK open wire inspection | OFF | There is less than 1 Ohm | |||
| GND open wire inspection | OFF | There is less than 1 Ohm | |||
| DR_SILCON_UNLOCK shorted to ground inspection | OFF | There is more than 1 MOhm | |||
Results
- If abnormal, there is a problem in the circuit.
DR_KEY_CYL_LOCK, GND Circuit Inspection
Test Procedure
- Preparation
- -
Driver's door latch connector (10P): disconnected
- -
Power window master switch 37P connector: disconnected
- -
- Procedure
- -
Perform the inspection according to the following chart.
- -
| (Disconnected) Driver's door latch connector (10P) female terminals | (Disconnected) Power window master switch 37P connector female terminals | ||||
| IG Mode |
|
|
Normal Conditions | ||
| DR_KEY_CYL_LOCK open wire inspection | OFF | There is less than 1 Ohm | |||
| GND open wire inspection | OFF | There is less than 1 Ohm | |||
| DR_KEY_CYL_LOCK shorted to ground inspection | OFF | There is more than 1 MOhm | |||
Results
- If abnormal, there is a problem in the circuit.
FR_DOOR_SW, GND Open Wire Inspection
Test Procedure
- Preparation
- -
Front passenger's door latch connector (10P): disconnected
- -
Body control module connector B (66P): disconnected
- -
- Procedure
- -
Perform the inspection according to the following chart.
- -
| (Disconnected) Front passenger's door latch connector (10P) female terminals | (Disconnected) Body control module connector B (66P) female terminals |
| IG Mode |
|
|
Normal Conditions | ||
| FR_DOOR_SW open wire inspection | OFF | There is less than 1 Ohm | |||
| GND open wire inspection | OFF | There is less than 1 Ohm | |||
Results
- If abnormal, there is a problem in the circuit.
AS_SILCON_UNLOCK, GND Circuit Inspection
Test Procedure
- Preparation
- -
Front passenger's door latch connector (10P): disconnected
- -
Front passenger's power window switch 37P connector: disconnected
- -
- Procedure
- -
Perform the inspection according to the following chart.
- -
| (Disconnected) Front passenger's door latch connector (10P) female terminals | (Disconnected) Front passenger's power window switch 37P connector female terminals | ||||
| IG Mode |
|
|
Normal Conditions | ||
| AS_SILCON_UNLOCK open wire inspection | OFF | There is less than 1 Ohm | |||
| GND open wire inspection | OFF | There is less than 1 Ohm | |||
| AS_SILCON_UNLOCK shorted to ground inspection | OFF | There is more than 1 MOhm |
Results
- If abnormal, there is a problem in the circuit.
RL_DOOR_SW, GND Open Wire Inspection
Test Procedure
- Preparation
- -
Left rear door latch connector (10P): disconnected
- -
Body control module connector B (66P): disconnected
- -
- Procedure
- -
Perform the inspection according to the following chart.
- -
| (Disconnected) Left rear door latch connector (10P) female terminals | (Disconnected) Body control module connector B (66P) female terminals | ||||
| IG Mode |
|
|
Normal Conditions | ||
| RL_DOOR_SW open wire inspection | OFF | There is less than 1 Ohm | |||
| GND open wire inspection | OFF | There is less than 1 Ohm | |||
Results
- If abnormal, there is a problem in the circuit.
RR_L_SILCON_UNLOCK, GND Circuit Inspection
Test Procedure
- Preparation
- -
Left rear door latch connector (10P): disconnected
- -
Body control module connector B (66P): disconnected
- -
- Procedure
- -
Perform the inspection according to the following chart.
- -
| (Disconnected) Left rear door latch connector (10P) female terminals | (Disconnected) Body control module connector B (66P) female terminals | ||||
| IG Mode |
|
|
Normal Conditions | ||
| RR_L_SILCON_UNLOCK open wire inspection | OFF | There is less than 1 Ohm | |||
| GND open wire inspection | OFF | There is less than 1 Ohm | |||
| RR_L_SILCON_UNLOCK shorted to ground inspection | OFF | There is more than 1 MOhm | |||
Results
- If abnormal, there is a problem in the circuit.
RR_DOOR_SW, GND Open Wire Inspection
Test Procedure
- Preparation
- -
Right rear door latch connector (10P): disconnected
- -
Body control module connector B (66P): disconnected
- -
- Procedure
- -
Perform the inspection according to the following chart.
- -
| (Disconnected)Right rear door latch connector (10P) female terminals | (Disconnected)Body control module connector B (66P) female terminals | ||||
| IG Mode |
|
|
Normal Conditions | ||
| RR_DOOR_SW open wire inspection | OFF | There is less than 1 Ohm | |||
| GND open wire inspection | OFF | There is less than 1 Ohm | |||
Results
- If abnormal, there is a problem in the circuit.
RR_R_SILCON_UNLOCK, GND Circuit Inspection
Test Procedure
- Preparation
- -
Right rear door latch connector (10P): disconnected
- -
Body control module connector B (66P): disconnected
- -
- Procedure
- -
Perform the inspection according to the following chart.
- -
| (Disconnected) Right rear door latch connector (10P) female terminals | (Disconnected) Body control module connector B (66P) female terminals |
| IG Mode |
|
|
Normal Conditions | ||
| RR_R_SILCON_UNLOCK open wire inspection | OFF | There is less than 1 Ohm | |||
| GND open wire inspection | OFF | There is less than 1 Ohm | |||
| RR_R_SILCON_UNLOCK shorted to ground inspection | OFF | There is more than 1 MOhm | |||
Results
- If abnormal, there is a problem in the circuit.
TAIL_GATE_SW, GND Circuit Inspection
Test Procedure
- Preparation
- -
Tailgate latch connector (4P): disconnected
- -
Body control module connector B (66P): disconnected
- -
- Procedure
- -
Perform the inspection according to the following chart.
- -
| (Disconnected) Tailgate latch connector (4P) female terminals | (Disconnected) Body control module connector B (66P) female terminals |
| IG Mode |
|
|
Normal Conditions | ||
| TAIL_GATE_SW open wire inspection | OFF | There is less than 1 Ohm | |||
| GND open wire inspection | OFF | There is less than 1 Ohm | |||
| TAIL_GATE_SW shorted to ground inspection | OFF | There is more than 1 MOhm | |||
Results
- If abnormal, there is a problem in the circuit.
Body Control Module Inspection
Test Procedure
- If the other inspection item(s) indicated a normal condition, then it is determined that the remaining body control module is the cause.
Results
- There is a problem with the body control module.