Turn ignition switch to LOCK position. Using a voltmeter, backprobe appropriate terminals at Smart Entrance Control Unit (SECU) harness connector with appropriate door in appropriate position. See DOOR SWITCH INPUT VOLTAGE TEST
table. See Figure
. If voltage is not as specified, go to next step. If voltage is as specified, door switch input signals are okay at this time.DOOR SWITCH INPUT VOLTAGE TEST
| Door Position |
Terminal No. (Wire Color) |
Voltage |
| Driver's Door |
| Open |
15 (Green/Red) |
0 |
| Closed |
15 (Green/Red) |
12 |
| Passenger's Door |
| Open |
35 (Yellow) |
0 |
| Closed |
35 (Yellow) |
12 |
| Any Door |
| Open |
16 (Red/Yellow) |
0 |
| Closed |
16 (Red/Yellow) |
12 |