Encoder And Limit Switch Check
- CHECK DOOR WINDOW SLIDE MECHANISM
Check the following.
Obstacles in window, glass molding, etc.
Worn or deformed glass molding
Door sash tilted too far inward or outward
Door window regulator
OK or NG
OK: GO TO 2.
NG: Remove obstacles or repair door window slide mechanism.
- CHECK POWER SUPPLY TO LIMIT SWITCH
- Disconnect front power window regulator LH or RH harness connector.
- Check voltage between front power window main switch terminal 15 or front power window switch RH terminal 16 and ground.
NOTE: Check voltage when front power window regulator LH or RH harness connector is disconnected.OK or NG
OK: GO TO 3.
NG: Replace power window main switch or front power window switch RH.
- CHECK LIMIT SWITCH OPERATION
- Connect front power window regulator LH or RH.
- Check voltage between front power window main switch terminal 15 or front power window switch RH terminal 16 and ground during power window closing operation.
OK or NG
OK: GO TO 5.
NG: GO TO 4.
- RESET LIMIT SWITCH
Reset limit switch. Refer to "FRONT DOOR GLASS LIMIT SWITCH RESET ". Then check voltage between front power window main switch terminal 15 or front power window switch RH terminal 16 and ground during power window closing operation at least ten times.
OK or NG
OK: GO TO 5.
NG: Replace power window regulator.
- CHECK ENCODER
Measure voltage between front power window main switch terminal 14 or front power window switch RH terminal 19 and ground with oscilloscope when power window is in automatic closing operation.
OK or NG
OK: Replace power window main switch or front power window switch RH.
NG: Replace power window regulator.