Diagnosis Procedure
- CHECK CONTINUITY VERTICAL SYNCHRONIZING (VP) SIGNAL CIRCUIT
- Turn ignition switch OFF.
- Disconnect display unit connector and AV control unit connector.
- Check continuity between display unit harness connector and AV control unit harness connector.TERMINALS CONTINUITY SPECIFICATION
Display unit AV control unit Continuity Connector Terminal Connector Terminal M71 20 M83 57 Existed - Check continuity between display unit harness connector and ground.TERMINALS CONTINUITY SPECIFICATION
Display unit Ground Continuity Connector Terminal M71 20 Not existed
Is the inspection result normal?
YES: GO TO 2.
NO: Repair harness or connector.
- CHECK VERTICAL SYNCHRONIZING (VP) SIGNAL
- Connect display unit connector and AV control unit connector.
- Turn ignition switch ON.
- Check signal between display unit harness connector and ground.TERMINALS REFERENCE
(+) (-) Reference value Display unit Connector Terminal M71 20 Ground
Is the inspection result normal?
YES: Replace AV control unit.
NO: Replace display unit.