Component Inspection
- CHECK EXHAUST VALVE TIMING CONTROL MAGNET RETARDER
- Turn ignition switch OFF.
- Disconnect exhaust valve timing control magnet retarder harness connector.
- Check resistance between exhaust valve timing control magnet retarder terminals as follows.RESISTANCE SPECIFICATIONS
Terminals Resistance 1 and 2 9.0 - 11.0 Ω [at 20°C (68°F)]
Is the inspection result normal?
YES: INSPECTION END
NO: GO TO 2.
- REPLACE EXHAUST VALVE TIMING CONTROL MAGNET RETARDER
- Replace malfunctioning exhaust valve timing control magnet retarder.
- Perform
"EXHAUST VALVE TIMING CONTROL LEARNING : SPECIAL REPAIR REQUIREMENT
".
INSPECTION END