Check Remote Keyless Entry Receiver
- CHECK REMOTE KEYLESS ENTRY RECEIVER OUTPUT SIGNAL
- Turn ignition switch OFF.
- Check remote keyless entry receiver connector M98 terminal 2 (L) and ground signal with oscilloscope.
Courtesy of NISSAN MOTOR CO., U.S.A.NISSAN MOTOR CO., U.S.A.NISSAN MOTOR CO., U.S.A.
REMOTE KEYLESS ENTRY RECEIVER OUTPUT SIGNALConnector Terminal (Wire color) Condition of keyfob Voltage (Reference value) (+) (-) M98 2 Ground No function Any button is pressed
OK or NG
OK: Remote keyless entry receiver circuit is OK.
NG: GO TO 2.
- CHECK REMOTE KEYLESS ENTRY RECEIVER INPUT VOLTAGE
- Disconnect remote keyless entry receiver connector.
- Check voltage between remote keyless entry receiver connector M98 terminal 4 (R) and ground.
4 (Y) - Ground : Approx. 4.5V
OK or NG
OK: GO TO 4.
NG: GO TO 3.
- CHECK REMOTE KEYLESS ENTRY RECEIVER POWER SUPPLY CIRCUIT
- Disconnect BCM connector.
- Check continuity between remote keyless entry receiver connector M78 terminal 4 (R) and BCM connector M1 terminal 19 (R).
4 (R) - 19 (R) : Continuity should exist.
- Check continuity between remote keyless entry receiver connector M78 terminal 4 (R) and ground.
4 (R) - Ground : Continuity should not exist.
OK or NG
OK: Check harness connection.
- If it is OK, replace BCM.
- If it is NG, repair or replace malfunction part.
NG: Repair or replace the harness.
- CHECK REMOTE KEYLESS ENTRY RECEIVER GROUND CIRCUIT
- Check continuity between remote keyless entry receiver connector M78 terminal 1 (B) and ground.
1 (B) - Ground : Continuity should exist.
OK or NG
OK: GO TO 6.
NG: GO TO 5.
- Check continuity between remote keyless entry receiver connector M78 terminal 1 (B) and ground.
- CHECK REMOTE KEYLESS ENTRY RECEIVER GROUND CIRCUIT
- Check continuity between remote keyless entry receiver connector M78 terminal 1 (B) and BCM connector M1 terminal 18 (B)
1 (B) - 18 (B) : Continuity should exist.
OK or NG
OK: Check harness connection.
- If it is OK, replace BCM.
- If it is NG, repair or replace malfunction part.
NG: Repair or replace the harness.
- Check continuity between remote keyless entry receiver connector M78 terminal 1 (B) and BCM connector M1 terminal 18 (B)
- CHECK REMOTE KEYLESS ENTRY RECEIVER SIGNAL CIRCUIT
- Check continuity between remote keyless entry receiver connector M78 terminal 2 (Y) and BCM connector M1 terminal 20 (Y).
2 (Y) - 20 (Y) : Continuity should exist.
- Check continuity between remote keyless entry receiver connector M78 terminal 2 (Y) and ground.
2 (Y) - Ground : Continuity should not exist.
OK or NG
OK: Check harness connection.
- If it is OK, replace remote keyless entry receiver.
- If it is NG, repair or replace malfunction part.
NG: Repair or replace harness.
- Check continuity between remote keyless entry receiver connector M78 terminal 2 (Y) and BCM connector M1 terminal 20 (Y).