System Initialization
If any of the following work has been done, initialize the system.
- Electric power supply to power window switch or motor is interrupted by blown fuse or disconnecting battery cable, etc.
- Removal and installation of the regulator assembly.
- Removal and installation of the motor from the regulator assembly.
- Removal and installation of the harness connector of the power window switch.
- Operation of the regulator assembly as a unit.
- Removal and installation of the door glass.
- Removal and installation of the door glass run.
Initialization
After installing each component to the vehicle, follow the steps below.
- Disconnect the minus terminal of battery or disconnect power window switch harness connector temporarily, then reconnect after at least 1 minute.
- Turn ignition switch ON.
- Operate power window switch to make over a half of the window area open.
- Fully draw the power window switch in the up direction (auto close position) and hold, keep holding the switch even when window is completely closed and then release after 3 seconds have passed.
- Inspection of the anti-pinch system function.NOTE: Initialization may be cancelled with continuous opening and closing operation. In this case, initialize the system.