Component Inspection
- CHECK PUSH-BUTTON IGNITION SWITCH
Check push-button ignition switch.
CONTINUITY SPECIFICATIONTerminal Push-button ignition switch position Continuity Push-button ignition switch 8 5 LOCK Existed 6 ACC 7 ON Is the inspection result normal?
YES: INSPECTION END
NO: Replace push-button ignition switch. Refer to , "REMOVAL AND INSTALLATION ".