Physical Values
TERMINAL PHYSICAL VALUES CHART
| Terminal No. | Wire color | Description | Condition | Value (Approx.) | ||
|---|---|---|---|---|---|---|
| + | - | Signal name | Input/Output | |||
| 1 | - | G | 4WAS front motor V terminal | - | - | - |
| 2 | Ground | W | Front wheel angle sensor W terminal voltage | Output | Ignition switch: ON | 0 - 5 V |
| 3 | - | B | 4WAS front lock solenoid valve ground | - | - | - |
| 4 | Ground | Y | Front wheel angle sensor U terminal voltage | Output | Ignition switch: ON | 0 - 5 V |
| 5 | - | BR | 4WAS front motor U terminal | - | - | - |
| 6 | - | L | 4WAS front motor W terminal | - | - | - |
| 7 | - | GR | Front wheel angle sensor ground | - | - | - |
| 8 | Ground | G/R | Front wheel angle sensor V terminal voltage | Output | Ignition switch: ON | 0 - 5 V |
| 10 | Ground | R | 4WAS front lock solenoid valve power supply | Output | Ignition switch: ON | Battery voltage |
| Ignition switch: OFF (Wait 10 min. or more.) | 0 V | |||||
| 11 | Ground | R | Power supply | Input | Ignition switch: ON | Battery voltage |
| Ignition switch: OFF | Battery voltage | |||||
| 12 | Ground | B | 4WAS front motor ground | - | Always | 0 V |
| 14 | - | Y | 4WAS communication-L | - | - | - |
| 15 | Ground | G | Ignition switch power supply | Input | Ignition switch: ON | Battery voltage |
| Ignition switch: OFF | 0 V | |||||
| 18 | Ground | B | Ground | - | Always | 0 V |
| 25 | - | SB | 4WAS communication-H | - | - | - |
| 34 | Ground | B | Ground | - | Always | 0 V |
CAUTION:
When using circuit tester to measure voltage for inspection, never extend forcibly any connector terminals.