Diagnosis Procedure
- CHECK GROUND CONNECTION
- Turn ignition switch OFF.
- Check ground connection M95. Refer to Ground Inspection in "CIRCUIT INSPECTION ".
Is the inspection result normal?
YES: GO TO 2.
NO: Repair or replace ground connection.
- CHECK CONNECTOR
- Disconnect EVAP control system pressure sensor harness connector.
- Check sensor harness connector for water.
Water should not exist.
Is the inspection result normal?
YES: GO TO 3.
NO: Repair or replace harness connector.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY CIRCUIT-I
- Turn ignition switch ON.
- Check the voltage between EVAP control system pressure sensor harness connector and ground.TERMINALS VOLTAGE REFERENCE
EVAP control system pressure sensor Ground Voltage Connector Terminal B252 3 Ground Approx. 5V
Is the inspection result normal?
YES: GO TO 10.
NO: GO TO 4.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY CIRCUIT-II
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.TERMINALS CONTINUITY REFERENCE
EVAP control system pressure sensor ECM Continuity Connector Terminal Connector Terminal B252 3 M107 107 Existed
Is the inspection result normal?
YES: GO TO 6.
NO: GO TO 5.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors M7, B1
- Harness connectors B31, B251
- Harness for open between ECM and EVAP control system pressure sensor
Repair open circuit.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY CIRCUIT-III
Check harness for short to power and short to ground, between the following terminals.
CONNECTOR TERMINALS REFERENCEECM Sensor Connector Terminal Name Connector Terminal F101 46 CKP sensor (POS) F2 1 F102 64 CMP sensor (PHASE) (bank 2) F18 1 EVT control position sensor (bank 2) F19 1 Battery current sensor E21 1 M107 103 APP sensor E112 6 107 EVAP control system pressure sensor B252 3 111 Refrigerant pressure sensor E77 3 Is the inspection result normal?
YES: GO TO 7.
NO: Repair short to ground or short to power in harness or connectors.
- CHECK COMPONENTS
Check the following.
- Crankshaft position sensor (POS) (Refer to "COMPONENT INSPECTION ".)
- Camshaft position sensor (PHASE) (bank 2) (Refer to "COMPONENT INSPECTION ".)
- Exhaust valve timing control position sensor (bank 2) (Refer to "COMPONENT INSPECTION ".)
- Battery current sensor (Refer to "COMPONENT INSPECTION ".)
- Refrigerant pressure sensor (Refer to "COMPONENT INSPECTION ".)
Is the inspection result normal?
YES: GO TO 8.
NO: Replace malfunctioning component.
- CHECK APP SENSOR
Refer to "COMPONENT INSPECTION ".
Is the inspection result normal?
YES: GO TO 15.
NO: GO TO 9.
- REPLACE ACCELERATOR PEDAL ASSEMBLY
- Replace accelerator pedal assembly
- Go to
"SPECIAL REPAIR REQUIREMENT
".
INSPECTION END
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR GROUND CIRCUIT FOR OPEN AND SHORT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.TERMINALS CONTINUITY REFERENCE
EVAP control system pressure sensor ECM Continuity Connector Terminal Connector Terminal B252 1 M107 112 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES: GO TO 12.
NO: GO TO 11.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors B251, B31
- Harness connectors B1, M7
- Harness for open or short between EVAP control system pressure sensor and ECM
Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
- Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.TERMINALS CONTINUITY REFERENCE
EVAP control system pressure sensor ECM Continuity Connector Terminal Connector Terminal B252 2 M107 102 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES: GO TO 14.
NO: GO TO 13.
- Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors B251, B31
- Harness connectors B1, M7
- Harness for open or short between EVAP control system pressure sensor and ECM
Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR
Refer to "COMPONENT INSPECTION ".
Is the inspection result normal?
YES: GO TO 15.
NO: Replace EVAP control system pressure sensor.
- CHECK INTERMITTENT INCIDENT
Refer to "INTERMITTENT INCIDENT ".
INSPECTION END