IPDM E/R (INTELLIGENT POWER DISTRIBUTION MODULE ENGINE ROOM) : Diagnosis Procedure
- CHECK FUSES AND FUSIBLE LINK
Check that the following IPDM E/R fuses or fusible links are not blown.
IPDM E/R FUSE AND FUSIBLE LINK NO. REFERENCETerminal No. Signal name Fuses and fusible link No. 1 Battery power supply C - 50 51 Is the fuse fusing?
YES: Replace the blown fuse or fusible link after repairing the affected circuit if a fuse or fusible link is blown.
NO: GO TO 2.
- CHECK POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Disconnect IPDM E/R connector.
- Check voltage between IPDM E/R harness connector and ground.VOLTAGE SPECIFICATION
Terminals Voltage (Approx.) (+) (-) IPDM E/R Connector Terminal Ground E4 1 Battery voltage 2
Is the measurement value normal?
YES: GO TO 3.
NO: Repair harness or connector.
- CHECK GROUND CIRCUIT
Check continuity between IPDM E/R harness connectors and ground.
CONTINUITY SPECIFICATIONIPDM E/R Ground Continuity Connector Terminal E5 12 Existed E6 41 Does continuity exist?
YES: INSPECTION END
NO: Repair harness or connector.