Component Inspection
- CHECK THROTTLE POSITION SENSOR
- Turn ignition switch OFF.
- Reconnect all harness connectors disconnected.
- Perform "THROTTLE VALVE CLOSED POSITION LEARNING : SPECIAL REPAIR REQUIREMENT ".
- Turn ignition switch ON.
- Set selector lever to D (A/T) or 1st (M/T) position.
- Check the voltage between ECM harness connector and ground.TERMINALS VOLTAGE REFERENCE
ECM Ground Condition Voltage Connector Terminal F101 30 [TP sensor 1 (bank 1)]
31 [TP sensor 1 (bank 2)]Ground Accelerator pedal Fully released More than 0.36V Fully depressed Less than 4.75V 34 [TP sensor 2 (bank 1)]
35 [TP sensor 2 (bank 2)]Fully released Less than 4.75V Fully depressed More than 0.36V
Is the inspection result normal?
YES: INSPECTION END
NO: GO TO 2.
- REPLACE ELECTRIC THROTTLE CONTROL ACTUATOR
- Replace malfunctioning electric throttle control actuator.
- Go to
"SPECIAL REPAIR REQUIREMENT ".
INSPECTION END