Diagnosis Procedure
- INSPECTION START
Start engine.
Is engine running?
YES: GO TO 8.
NO: GO TO 2.
- CHECK ECM POWER SUPPLY CIRCUIT-I
- Turn ignition switch OFF and then ON.
- Check the voltage between ECM harness connector and ground.ECM CONNECTOR TERMINAL AND CONTINUITY CHART
ECM Ground Voltage Connector Terminal F102 53 Ground Battery voltage
Is the inspection result normal?
YES: GO TO 4.
NO: GO TO 3.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors E3, F1
- IPDM E/R harness connector E7
- 10A fuse (No. 44)
- Harness for open or short between ECM and fuse
Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK GROUND CONNECTION-I
- Turn ignition switch OFF.
- Check ground connection M95. Refer to Ground Inspection in "CIRCUIT INSPECTION ".
Is the inspection result normal?
YES: GO TO 5.
NO: Repair or replace ground connection.
- CHECK ECM GROUND CIRCUIT FOR OPEN AND SHORT-I
- Disconnect ECM harness connector.
- Check the continuity between ECM harness connector and ground.ECM CONNECTOR TERMINAL AND VOLTAGE CHART
ECM Ground Continuity Connector Terminal F101 8 Ground Existed M107 123 124 127 128 - Also check harness for short to power.
Is the inspection result normal?
YES: GO TO 7.
NO: GO TO 6.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors F103, M116
- Harness for open or short between ECM and ground
Repair open circuit or short to power in harness or connectors.
- CHECK ECM POWER SUPPLY CIRCUIT-II
- Reconnect ECM harness connector.
- Turn ignition switch ON.
- Check the voltage between IPDM E/R harness connector and ground.ECM CONNECTOR TERMINAL AND VOLTAGE CHART
IPDM E/R Ground Voltage Connector Terminal E7 53 Ground Battery voltage
Is the inspection result normal?
YES: Go to "DIAGNOSIS PROCEDURE ".
NO: GO TO 8.
- CHECK ECM POWER SUPPLY CIRCUIT-III
- Turn ignition switch OFF and wait at least 10 seconds.
- Check the voltage between ECM harness connector and ground.ECM CONNECTOR TERMINAL AND VOLTAGE CHART
ECM Ground Voltage Connector Terminal M107 125 Ground After turning ignition switch OFF, battery voltage will exist for a few seconds, then drop approximately 0V.
Is the inspection result normal?
YES: GO TO 15.
NO-1: Battery voltage does not exist: GO TO 9.
NO-2: Battery voltage exists for more than a few seconds: GO TO 12.
- CHECK ECM POWER SUPPLY CIRCUIT-IV
- Turn ignition switch OFF and wait at least 10 seconds.
- Check the voltage between ECM harness connector and ground.ECM CONNECTOR TERMINAL AND VOLTAGE CHART
ECM Ground Voltage Connector Terminal F101 24 Ground Battery voltage
Is the inspection result normal?
YES: GO TO 10.
NO: GO TO 12.
- CHECK ECM POWER SUPPLY CIRCUIT-V
- Disconnect ECM harness connector.
- Disconnect IPDM E/R harness connector E7.
- Check the continuity between ECM harness connector and IPDM E/R harness connector.ECM CONNECTOR TERMINAL AND CONTINUITY CHART
ECM IPDM E/R Continuity Connector Terminal Connector Terminal M107 125 E7 49 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES: GO TO 18.
NO: GO TO 11.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness or connectors E106, M6
- Harness for open or short between ECM and IPDM E/R
Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK ECM POWER SUPPLY CIRCUIT-VI
- Disconnect ECM harness connector.
- Disconnect IPDM E/R harness connector E7.
- Check the continuity between ECM harness connector and IPDM E/R harness connector.ECM CONNECTOR TERMINAL AND CONTINUITY CHART
ECM IPDM E/R Continuity Connector Terminal Connector Terminal F101 24 E7 69 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES: GO TO 14.
NO: GO TO 13.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness or connectors E3, F1
- Harness connectors F104, F105
- Harness for open or short between ECM and IPDM E/R
Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK 15A FUSE
- Disconnect 15A fuse (No. 50) from IPDM E/R.
- Check 15A fuse.
Is the inspection result normal?
YES: GO TO 18.
NO: Replace 15A fuse.
- CHECK GROUND CONNECTION-II
Check ground connection M95. Refer to Ground Inspection in "CIRCUIT INSPECTION ".
Is the inspection result normal?
YES: GO TO 16.
NO: Repair or replace ground connection.
- CHECK ECM GROUND CIRCUIT FOR OPEN AND SHORT-II
- Disconnect ECM harness connector.
- Check the continuity between ECM harness connector and ground.ECM CONNECTOR TERMINAL AND CONTINUITY CHART
ECM Ground Continuity Connector Terminal F101 8 Ground Existed M107 123 124 127 128 - Also check harness for short to power.
Is the inspection result normal?
YES: GO TO 18.
NO: GO TO 17.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness or connectors F103, M116
- Harness for open or short between ECM and ground
Repair open circuit or short to power in harness or connectors.
- CHECK INTERMITTENT INCIDENT
Refer to "INTERMITTENT INCIDENT ".
Is the inspection result normal?
YES: Replace IPDM E/R.
NO: Repair open circuit or short to ground or short to power in harness or connectors.