Component Description
The fuel tank temperature sensor (3) is used to detect the fuel temperature inside the fuel tank. The sensor modifies a voltage signal from the ECM. The modified signal returns to the ECM as the fuel temperature input. The sensor uses a thermistor which is sensitive to the change in temperature. The electrical resistance of the thermistor decreases as temperature increases.
- Fuel level sensor unit and fuel pump (1)
- Fuel pressure regulator (2)Fig 1: Identifying Fuel Level Sensor Unit And Fuel Pump, Fuel Pressure Regulator And Fuel Tank Temperature Sensor
Courtesy of NISSAN MOTOR CO., U.S.A.
< Reference data >
REFERENCE DATAFluid temperature °C (°F) Voltage(1) V Resistance kΩ 20 (68) 3.5 2.3 - 2.7 50 (122) 2.2 0.79 - 0.90 (1) This data is reference value and is measured between ECM terminal 107 (Fuel tank temperature sensor) and ground. CAUTION: Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in damage to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.