Component Inspection
- CHECK VDC OFF SWITCH
- Turn the ignition switch OFF.
- Disconnect VDC OFF switch connector.
- Check the continuity between VDC OFF switch connector terminals.TERMINAL CONTINUITY REFERENCE
VDC OFF switch Condition Continuity Terminal 1 - 2 When VDC OFF switch is hold pressed. Existed When releasing VDC OFF switch. Not existed Is the inspection result normal?
YES: INSPECTION END
NO: Replace VDC OFF switch.