Diagnosis Procedure
- CHECK CAMERA CONNECTION RECOGNITION SIGNAL CIRCUIT
- Disconnect AV control unit connector and camera control unit connector.
- Check continuity between AV control unit harness connector and camera control unit harness connector.CONNECTOR TERMINALS CONTINUITY REFERENCE CHART
AV control unit Camera control unit Continuity Connector Terminal Connector Terminal M87 40 B241 14 Existed Is the inspection result normal?
YES: GO TO 2.
NO: Repair harness or connector.
- CHECK AV CONTROL UNIT VOLTAGE
- Connect AV control unit connector.
- Turn ignition switch ON.
- Check voltage between AV control unit harness connector and ground.CONNECTOR TERMINALS VOLTAGE REFERENCE CHART
(+) (-) Voltage (Approx.) AV control unit Connector Terminal M87 40 Ground 5.0 V Is the inspection result normal?
YES: Replace camera control unit.
NO: Replace AV control unit.