Diagnosis Procedure
- CHECK CONTINUITY VERTICAL SYNCHRONIZING (VP) SIGNAL CIRCUIT
- Turn ignition switch OFF.
- Disconnect display unit connector and AV control unit connector.
- Check continuity between display unit harness connector and AV control unit harness connector.CONNECTOR TERMINALS CONTINUITY REFERENCE CHART
Display unit AV control unit Continuity Connector Terminal Connector Terminal M75 20 M88 69 Existed - Check continuity between display unit harness connector and ground.CONNECTOR TERMINALS CONTINUITY REFERENCE CHART
Display unit Ground Continuity Connector Terminal M75 20 Not existed Is the inspection result normal?
YES: GO TO 2.
NO: Repair harness or connector.
- CHECK VERTICAL SYNCHRONIZING (VP) SIGNAL
- Connect display unit connector and AV control unit connector.
- Turn ignition switch ON.
- Check signal between display unit harness connector and ground.CONNECTOR TERMINALS SIGNAL CHECK REFERENCE CHART
(+) (-) Reference value Display unit Connector Terminal M75 20 Ground Is the inspection result normal?
YES: Replace AV control unit.
NO: Replace display unit.