Diagnosis Procedure
- CHECK CONTINUITY CAMERA IMAGE SIGNAL CIRCUIT
- Turn ignition switch OFF.
- Disconnect camera control unit connector and AV control unit connector.
- Check continuity between camera control unit harness connector and AV control unit harness connector.CONTINUITY SPECIFICATION
Camera control unit AV control unit Continuity Connector Terminal Connector Terminal B241 12 M84 65 Existed 11 64 - Check continuity between camera control unit harness connector and ground.CONTINUITY SPECIFICATION
Camera control unit Ground Continuity Connector Terminal B241 12 Not existed Is the inspection result normal?
YES: GO TO 2.
NO: Repair harness or connector.
- CHECK CAMERA IMAGE SIGNAL
- Connect camera control unit connector and AV control unit connector.
- Turn ignition switch ON.
- Check signal between camera control unit harness connector and ground using an oscilloscope.SIGNAL SPECIFICATION
(+) (-) Condition Signal Camera control unit Connector Terminal B241 12 Ground Shift the selector lever to "R" position. Is the inspection result normal?
YES: Replace AV control unit.
NO: Replace camera control unit.