Sequence Of Roof Latch State
There are 3 states in roof latch. Open and close operations of retractable hard top system are performed interlocking with other retractable hard top system components. (For interlocking with other components, refer to "SYSTEM DESCRIPTION ").
Parts state (CONSULT-III display) according to sequential roof latch operations is as shown in the following table.
Lock Operation
CONSULT-III DATA MONITOR ITEM CHART
| - | Parts state | ||||||||
|---|---|---|---|---|---|---|---|---|---|
| Input parts | Output parts | ||||||||
| Roof latch status sensor | Roof latch lock sensor | Roof latch limit switch | Roof latch motor (UNLOCK) | Roof latch motor (LOCK) | |||||
| CONSULT-III datamonitor item | |||||||||
| LATCH STATE | LATCH VALUE | LATCH LOCK SEN | LATCH LIMIT SW | LATCH OUT(ULK) | LATCH OUT(LCK) | ||||
| Status on CONSULT-III | |||||||||
| OPEN | 78 or more | OFF | OPEN | OFF | ON | ||||
| MID | 77-1 | OFF | OPEN | OFF | ON | ||||
| CLOSE | 0 | ON | CLOSE(1)/OPEN(2) | OFF | OFF | ||||
|
|||||||||
Unlock Operation
CONSULT-III DATA MONITOR ITEM CHART
| - | Parts state | ||||||||
|---|---|---|---|---|---|---|---|---|---|
| Input parts | Output parts | ||||||||
| Roof latch status sensor | Roof latch status sensor | Roof latch limit switch | Roof latch motor (UNLOCK) | Roof latch motor (LOCK) | |||||
| CONSULT-III datamonitor item | |||||||||
| LATCH STATE | LATCH VALUE | LATCH STATE SEN | LATCH LIMIT SWITCH | LATCH OUT(ULK) | LATCH OUT(LCK) | ||||
| Status on CONSULT-III | |||||||||
| CLOSE | 0 | ON | CLOSE(1)/OPEN(2) | ON | OFF | ||||
| MID | 77-1 | OFF | OPEN | ON | OFF | ||||
| OPEN | 78 or more | OFF | OPEN | OFF | OFF | ||||
|
|||||||||