POWER WINDOW SUB-SWITCH : Component Function Check
- CHECK POWER WINDOW SWITCH OUTPUT SIGNAL
With CONSULT-III
Check ("CDL LOCK SW", "CDL UNLOCK SW") in "DATA MONITOR" mode for "POWER DOOR LOCK SYSTEM" with CONSULT-III. Refer to "COMMON ITEM : CONSULT-III FUNCTION (BCM - COMMON ITEM) ".
MONITOR ITEM CONDITION CHARTMonitor item Condition CDL LOCK SW LOCK ON UNLOCK OFF CDL UNLOCK SW LOCK OFF UNLOCK ON Is the inspection result normal?
YES: Power window serial link is OK.
NO: Refer to "POWER WINDOW SUB-SWITCH : DIAGNOSIS PROCEDURE ".