Diagnosis Procedure
- INSPECTION START
Perform inspection in accordance with procedure that confirms DTC.
Which procedure confirms DTC?
DTC confirmation procedure 1: GO TO 2.
DTC confirmation procedure 2: GO TO 6.
- CHECK BCM OUTPUT SIGNAL-1
- Turn ignition switch OFF.
- Disconnect steering lock unit connector and IPDM E/R connector.
- Check voltage between steering lock unit harness connector and ground.VOLTAGE SPECIFICATION
(+) (-) Voltage (V) (Approx.) Steering lock unit Connector Terminal M40 3 Ground Battery voltage Is the inspection result normal?
YES: GO TO 4.
NO: GO TO 3.
- CHECK STEERING LOCK UNIT CIRCUIT-1
- Disconnect BCM connector.
- Check continuity between steering lock unit harness connector and BCM harness connector.CONTINUITY CHART
Steering lock unit BCM Continuity Connector Terminal Connector Terminal M40 3 M122 97 Existed - Check continuity between steering lock unit harness connector and ground.CONTINUITY CHART
Steering lock unit Ground Continuity Connector Terminal M40 3 Not existed Is the inspection result normal?
YES: Replace BCM. Refer to "REMOVAL AND INSTALLATION ".
NO: Repair or replace harness.
- CHECK IPDM E/R OUTPUT SIGNAL-1
- Connect IPDM E/R connector.
- Disconnect BCM connector.
- Check voltage between steering lock unit harness connector and ground.VOLTAGE SPECIFICATION
(+) (-) Voltage (V) (Approx.) Steering lock unit Connector Terminal M40 3 Ground Battery voltage Is the inspection result normal?
YES: Replace steering lock unit.
NO: GO TO 5.
- CHECK STEERING LOCK UNIT CIRCUIT-2
- Disconnect IPDM E/R connector.
- Check continuity between steering lock unit harness connector and IPDM E/R harness connector.CONTINUITY CHART
Steering lock unit IPDM E/R Continuity Connector Terminal Connector Terminal M40 3 E5 32 Existed - Check continuity between steering lock unit harness connector and ground.CONTINUITY CHART
Steering lock unit Ground Continuity Connector Terminal M40 3 Not existed Is the inspection result normal?
YES: Replace IPDM E/R. Refer to "REMOVAL AND INSTALLATION ".
NO: Repair or replace harness.
- CHECK BCM OUTPUT SIGNAL-2
- Turn ignition switch OFF.
- Disconnect steering lock unit connector and IPDM E/R connector.
- Check voltage between steering lock unit harness connector and ground.VOLTAGE SPECIFICATION
(+) (-) Voltage (V) (Approx.) Steering lock unit Connector Terminal M40 8 Ground Battery voltage Is the inspection result normal?
YES: GO TO 8.
NO: GO TO 7.
- CHECK STEERING LOCK UNIT CIRCUIT-3
- Disconnect BCM connector.
- Check continuity between steering lock unit harness connector and BCM harness connector.CONTINUITY CHART
Steering lock unit BCM Continuity Connector Terminal Connector Terminal M40 8 M122 98 Existed - Check continuity between steering lock unit harness connector and ground.CONTINUITY CHART
Steering lock unit Ground Continuity Connector Terminal M40 8 Not existed Is the inspection result normal?
YES: Replace BCM. Refer to "REMOVAL AND INSTALLATION ".
NO: Repair or replace harness.
- CHECK IPDM E/R OUTPUT SIGNAL-2
- Connect IPDM E/R connector.
- Disconnect BCM connector.
- Check voltage between steering lock unit harness connector and ground.VOLTAGE SPECIFICATION
(+) (-) Voltage (V) (Approx.) Steering lock unit Connector Terminal M40 8 Ground Battery voltage Is the inspection result normal?
YES: Replace steering lock unit.
NO: GO TO 9.
- CHECK STEERING LOCK UNIT CIRCUIT-4
- Disconnect IPDM E/R connector.
- Check continuity between steering lock unit harness connector and IPDM E/R harness connector.CONTINUITY CHART
Steering lock unit IPDM E/R Continuity Connector Terminal Connector Terminal M40 8 E5 33 Existed - Check continuity between steering lock unit harness connector and ground.CONTINUITY CHART
Steering lock unit Ground Continuity Connector Terminal M40 8 Not existed Is the inspection result normal?
YES: Replace IPDM E/R. Refer to "REMOVAL AND INSTALLATION ".
NO: Repair or replace harness.