System Description: Initialization
Perform the initialization when the following operations are performed or when the auto up operation is not performed. Refer to SYSTEM INITIALIZATION (Front door), SYSTEM INITIALIZATION (Rear door).
- When the power supply to the power window main switch, power window sub-switch or each power window motor is cut off by the removal of battery terminal or the battery fuse is blown.
- Disconnection and connection of power window main switch or each power window sub-switch harness connector.
- Removal and installation of regulator assembly.
- Removal and installation of motor from regulator assembly.
- Operation of regulator assembly as an independent unit.
- Removal and installation of glass.
- Removal and installation of door glass run.CAUTION: The following operations are not performed under the condition that the initialization is not performed yet.
- Auto up operation
- Anti-pinch function
- Key cylinder switch close operation