Terminals and Reference Values for Driver Seat Control Unit
WARNING: This page is about a different car, the 2008 Infiniti FX45 and 2008 Infiniti FX35. However, it is still accessible from the selected car via links, so may be relevant.
DRIVER SEAT CONTROL UNIT TERMINAL REFERENCE
| Terminal | Wire Color | Item | Signal Input/Output | Condition | Voltage (V) (Approx.) |
|---|---|---|---|---|---|
| 1A | R | Power source (Fusible link) | Input | - | Battery voltage |
| 2 | P | UART LINE (TX) | Output | Memory switch 1 or 2 operated | |
| 3 | G | Sliding motor FORWARD signal | Output | When sliding motor FORWARD operation | Battery voltage |
| Other than above | 0 | ||||
| 4 | G/L | Reclining motor FORWARD signal | Output | When reclining motor FORWARD operation | Battery voltage |
| Other than above | 0 | ||||
| 5 | LG | Front lifting motor DOWN signal | Output | When front lifting motor DOWN operation | Battery voltage |
| Other than above | 0 | ||||
| 6 | G/W | Rear lifting motor UP signal | Output | When rear lifting motor UP operation | Battery voltage |
| Other than above | 0 | ||||
| 7 | G/B | Rear lifting motor DOWN signal | Output | When rear lifting motor DOWN operation | Battery voltage |
| Other than above | 0 | ||||
| 8 | G/Y | UART LINE (RX) | Input | Memory switch 1 or 2 switch operated | |
| 9 | BR | Ignition switch (START) | Input | Ignition switch (START position) | Battery voltage |
| 10 | G/R | Sliding motor BACKWARD signal | Output | When sliding motor BACKWARD operation | Battery voltage |
| Other than above | 0 | ||||
| 11A | R/W | Power source (Fuse) | Input | - | Battery voltage |
| 12 | G/Y | Reclining motor BACKWARD signal | Output | When reclining motor BACKWARD operation | Battery voltage |
| Other than above | 0 | ||||
| 13 | Y | Front lifting motor UP signal | Output | When front lifting motor UP operation | Battery voltage |
| Other than above | 0 | ||||
| 14 | OR | CAN-H | Input/Output | - | - |
| 15 | SB | CAN-L | Input/Output | - | - |
| 16A | B | Ground (power) | - | - | 0 |
| 17 | PU | Park position switch signal | Input | Selector lever other than P position | Battery voltage |
| Selector lever is sifted to P position | 0 | ||||
| 18 | G/L | Seat sliding sensor signal | Input | ON (sliding motor operation) | |
| Other than above | 0 or 5 | ||||
| 19 | G/R | Front lifting sensor signal | Input | ON (front lifting motor operation) | |
| Other than above | 0 or 5 | ||||
| 22 | R/B | Power seat memory switch 1 signal | Input | Memory switch 1: ON | 0 |
| Memory switch 1: OFF | 5 | ||||
| 23 | Y/W | Power seat memory switch indictor 1 signal | Output | Memory switch 1: ON | 1 |
| Memory switch 1: OFF | Battery voltage | ||||
| 24 | L/R | Seat sliding switch FORWARD signal | Input | When seat sliding switch FORWARD operation | 0 |
| Other than above | Battery voltage | ||||
| 25 | L/OR | Seat reclining switch FORWARD signal | Input | When seat reclining switch FORWARD operation | 0 |
| Other than above | Battery voltage | ||||
| 26 | L/P | Front lifting switch UP signal | Input | When front lifting switch UP operation | 0 |
| Other than above | Battery voltage | ||||
| 27 | L | Rear lifting switch UP signal | Input | When rear lifting switch UP operation | 0 |
| Other than above | Battery voltage | ||||
| 28C | B/W | Ground (sensor) | - | - | 0 |
| 29 | G | Reclining sensor signal | Input | ON (reclining motor operation) | |
| Other than above | 0 or 5 | ||||
| 30 | R/W | Rear lifting sensor signal | Input | ON (rear lifting motor operation) | |
| Other than above | 0 or 5 | ||||
| 34 | L/W | Set switch signal | Input | Set witch: ON | 0 |
| Set witch: OFF | 5 | ||||
| 35 | L/B | Power seat memory switch 2 signal | Input | Memory switch 2: ON | 0 |
| Memory switch 2: OFF | 5 | ||||
| 36 | Y/G | Power seat memory switch indictor 2 signal | Output | Memory switch 2: ON | 1 |
| Memory switch 2: OFF | Battery voltage | ||||
| 37 | W | Seat sliding switch BACKWARD signal | Input | When seat sliding switch BACKWARD operation | 0 |
| Other than above | Battery voltage | ||||
| 38 | LG/B | Seat reclining switch BACKWARD signal | Input | When seat reclining switch BACKWARD operation | 0 |
| Other than above | Battery voltage | ||||
| 39 | L/G | Front lifting switch DOWN signal | Input | When front lifting switch DOWN operation | 0 |
| Other than above | Battery voltage | ||||
| 40 | L/Y | Rear lifting switch DOWN signal | Input | When rear lifting switch DOWN operation | 0 |
| Other than above | Battery voltage | ||||
| 61E | B/Y | Ground (signal) | - | - | 0 |