Component Inspection
- CHECK IGNITION RELAY
- Turn ignition switch OFF.
- Remove ignition relay.
- Check the continuity between ignition relay terminals.TERMINALS CONTINUITY REFERENCE CHART
Terminals Condition Continuity 3 and 5 12 V direct current supply between terminals 1 and 2 Existed No current supply Not existed Is the inspection result normal?
YES: INSPECTION END
NO: Replace Ignition relay.