Diagnosis Procedure
- CHECK CONTINUITY RGB SYNCHRONIZING SIGNAL CIRCUIT
- Turn ignition switch OFF.
- Disconnect display unit connector and AV control unit connector.
- Check continuity between display unit harness connector and AV control unit harness connector.CONTINUITY REFERENCE CHART
Display unit AV control unit Continuity Connector Terminal Connector Terminal M75 19 M88 65 Existed - Check continuity between display unit harness connector and ground.CONTINUITY REFERENCE CHART
Display unit Ground Continuity Connector Terminal M75 19 Not existed Is inspection result normal?
YES: GO TO 2.
NO: Repair harness or connector.
- CHECK RGB SYNCHRONIZING SIGNAL
- Connect display unit connector and AV control unit connector.
- Turn ignition switch ON.
- Check signal between display unit harness connector and ground.SIGNAL REFERENCE CHART
(+) (-) Condition Reference value Display unit Connector Terminal M75 19 Ground Start confirmation/adjustment mode, and then display color bar by selecting "Color Spectrum Bar" on DISPLAY DIAGNOSIS screen. Is inspection result normal?
YES: Replace display unit.