Diagnosis Procedure
- CHECK CONTINUITY SIDE CAMERA RH POWER SUPPLY AND GROUND CIRCUIT
- Turn ignition switch OFF.
- Disconnect control unit connector and door mirror (passenger side) connector.
- Check continuity between around view monitor control unit harness connector and door mirror (passenger side) harness connector.CONTINUITY REFERENCE CHART
Around view monitor control unit Door mirror (passenger side) Continuity Connector Terminals Connector Terminals B46 32 D33 18 Existed 34 6 - Check continuity between around view monitor control unit harness connector and ground.CONTINUITY REFERENCE CHART
Around view monitor control unit Ground Continuity Connector Terminal B46 34 Not existed Is inspection result normal?
YES: GO TO 2.
NO: Repair harness or connector.
- CHECK VOLTAGE SIDE CAMERA RH POWER SUPPLY
- Connect around view monitor control unit connector and door mirror (passenger side) connector.
- Turn ignition switch ON.
- Check voltage between around view monitor control unit harness connector and ground.VOLTAGE REFERENCE CHART
(+) (-) Condition Voltage (Approx.) Around view monitor control unit Connector Terminal B46 34 Ground "CAMERA" switch is ON or shift position is "R". 6.0 V Is inspection result normal?
YES: GO TO 3.
NO: Replace around view monitor control unit.
- CHECK CONTINUITY SIDE CAMERA RH IMAGE SIGNAL CIRCUIT
- Turn ignition switch OFF.
- Disconnect around view monitor control unit connector and door mirror (passenger side) connector.
- Check continuity between around view monitor control unit harness connector and door mirror (passenger side) harness connector.CONTINUITY REFERENCE CHART
Around view monitor control unit Door mirror (passenger side) Continuity Connector Terminals Connector Terminals B46 29 D33 5 Existed 30 17 - Check continuity between around view monitor control unit harness connector and ground.CONTINUITY REFERENCE CHART
around view monitor control unit Ground Continuity Connector Terminals B46 29, 30 Not existed Is inspection result normal?
YES: GO TO 4.
NO: Repair harness or connector.
- CHECK SIDE CAMERA RH IMAGE SIGNAL
- Connect around view monitor control unit connector and door mirror (passenger side) connector.
- Turn ignition switch ON.
- Check signal between around view monitor control unit harness connector.SIGNAL REFERENCE CHART
(+) (-) Condition Reference value Around view monitor control unit Around view monitor control unit Connector Terminal Connector Terminal B46 29 B46 30 "CAMERA" switch is ON or shift position is "R". Is inspection result normal?
YES: Replace around view monitor control unit.
NO: Replace side camera RH.