Diagnosis Procedure
- CHECK CONTINUITY VERTICAL SYNCHRONIZING (VP) SIGNAL CIRCUIT
- Turn ignition switch OFF.
- Disconnect front display unit connector and AV control unit connector.
- Check continuity between front display unit harness connector and AV control unit harness connector.TERMINAL CONTINUITY REFERENCE TABLE
Front display unit AV control unit Continuity Connector Terminal Connector Terminal M75 20 M88 69 Existed - Check continuity between front display unit harness connector and ground.TERMINAL CONTINUITY REFERENCE TABLE
Front display unit Ground Continuity Connector Terminal M75 20 Not existed Is inspection result normal?
YES: GO TO 2.
NO: Repair harness or connector.
- CHECK VERTICAL SYNCHRONIZING (VP) SIGNAL
- Connect front display unit connector and AV control unit connector.
- Turn ignition switch ON.
- Check signal between front display unit harness connector and ground.TERMINAL CONNECTOR REFERENCE TABLE
(+) (-) Reference value Front display unit Connector Terminal M75 20 Ground Is inspection result normal?
YES: Replace AV control unit.
NO: Replace front display unit.