Diagnosis Procedure
- CHECK GROUND CONNECTION
- Turn ignition switch OFF.
- Check ground connection M95. Refer to Ground Inspection in
CIRCUIT INSPECTION
.
Is the inspection result normal?
YES: GO TO 2.
NO: Repair or replace ground connection.
- CHECK ECM GROUND CIRCUIT FOR OPEN AND SHORT
- DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors F103, M116
- Harness for open or short between ECM and ground
Repair open circuit or short to power in harness or connectors.
- CHECK ECM POWER SUPPLY CIRCUIT-I
- DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors E3, F1
- IPDM E/R harness connector E7
- 10 A fuse (No. 44)
- Harness for open or short between ECM and fuse
Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK ECM POWER SUPPLY CIRCUIT-II
- Turn ignition switch OFF and wait at least 10 seconds.
- Check the voltage between ECM harness connector terminals as follows.VOLTAGE REFERENCE TABLE
ECM Voltage Connector + - Terminal Terminal M107 125 128 After turning ignition switch OFF, battery voltage will exist for a few seconds, then drop to approximately 0 V. Is the inspection result normal?
YES: GO TO 7.
NO: GO TO 9.
- CHECK ECM POWER SUPPLY CIRCUIT-III
- Turn ignition switch ON.
- Check the voltage between IPDM E/R harness connector and ground.VOLTAGE REFERENCE TABLE
IPDM E/R Ground Voltage Connector Terminal E7 53 Ground Battery voltage Is the inspection result normal?
YES: GO TO 8.
NO: Replace IPDM E/R.
- CHECK INTERMITTENT INCIDENT
Refer to INTERMITTENT INCIDENT .
INSPECTION END
- CHECK ECM POWER SUPPLY CIRCUIT-IV
- CHECK ECM POWER SUPPLY CIRCUIT-V
- Disconnect ECM harness connector.
- Disconnect IPDM E/R harness connector.
- Check the continuity between ECM harness connector and IPDM E/R harness connector.CONTINUITY CONDITIONS
ECM IPDM E/R Continuity Connector Terminal Connector Terminal F101 24 E7 69 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES: GO TO 12.
NO: GO TO 11.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors E3, F1
- Harness connectors F104, F105
- Harness for open or short between ECM and IPDM E/R
Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK 15 A FUSE
- Disconnect 15 A fuse (No. 50) from IPDM E/R.
- Check 15 A fuse.
Is the inspection result normal?
YES: GO TO 15.
NO: Replace 15 A fuse.
- CHECK ECM POWER SUPPLY CIRCUIT-V
- Disconnect ECM harness connector.
- Disconnect IPDM E/R harness connector.
- Check the continuity between ECM harness connector and IPDM E/R harness connector.CONTINUITY CONDITIONS
ECM IPDM E/R Continuity Connector Terminal Connector Terminal M107 125 E7 49 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES: GO TO 15.
NO: GO TO 14.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors E106, M6
- Harness for open or short between ECM and IPDM E/R
Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK INTERMITTENT INCIDENT
Refer to INTERMITTENT INCIDENT .
Is the inspection result normal?
YES: Replace IPDM E/R.
NO: Repair open circuit, short to ground or short to power in harness or connectors.