Component Inspection
- CHECK PUSH-BUTTON IGNITION SWITCH
- Turn ignition switch OFF.
- Disconnect push-button ignition switch connector.
- Check continuity between push-button ignition switch terminals.TERMINALS CONTINUITY REFERENCE
Terminal Condition Continuity Push-button ignition switch (+) (-) 5 8 Push-button ignition switch position LOCK Existed 6 ACC 7 ON 8 5 LOCK Not existed 6 ACC 7 ON Is the inspection result normal?
YES: INSPECTION END
NO: Replace push-button ignition switch. Refer to REMOVAL AND INSTALLATION .