DRIVER SIDE : Diagnosis Procedure
WARNING: This page is about a different car, the 2010 Nissan Armada. However, it is still accessible from the selected car via links, so may be relevant.
Regarding Wiring Diagram information, refer to "WIRING DIAGRAM ".
- CHECK ENCODER OPERATION
- Turn ignition switch ON.
- Check signal between main power window and door lock/unlock switch connector and ground with oscilloscope.TERMINAL REFERENCE CHART
Terminals Signal (Reference value) (+) (-) Main power window and door lock/unlock switch connector Terminal D7 9 Ground Refer to following signal 13 Courtesy of NISSAN MOTOR CO., U.S.A.
Is the inspection result normal?
YES: Check intermittent incident. Refer to "INTERMITTENT INCIDENT ".
NO: GO TO 2
- CHECK FRONT POWER WINDOW MOTOR LH POWER SUPPLY
- Disconnect front power window motor LH.
- Check voltage between front power window motor LH connector and ground.TERMINAL VOLTAGE REFERENCE CHART
Terminal Voltage (V) (Approx.) (+) (-) Front power window motor LH connector Terminal D9 4 Ground 10 Is the measurement value within the specification?
YES: GO TO 4
NO: GO TO 3
- CHECK HARNESS CONTINUITY 1
- Turn ignition switch OFF.
- Disconnect main power window and door lock/unlock switch.
- Check continuity between main power window and door lock/unlock switch connector and front power window motor LH connector.TERMINAL CONTINUITY REFERENCE CHART
Main power window and door lock/unlock switch connector Terminal Front power window motor LH connector Terminal Continuity D7 (A) 15 D9 (B) 4 Yes - Check continuity between main power window and door lock/unlock switch connector and ground.TERMINAL CONTINUITY REFERENCE CHART
Main power window and door lock/unlock switch connector Terminal Ground Continuity D7 (A) 15 No Is the inspection result normal?
YES: Replace main power window and door lock/unlock switch. Refer to "REMOVAL AND INSTALLATION ".
NO: Repair or replace harness.
- CHECK GROUND CIRCUIT
- CHECK HARNESS CONTINUITY 2
- Disconnect main power window and door lock/unlock switch.
- Check continuity between main power window and door lock/unlock switch connector and front power window motor LH connector.TERMINAL CONTINUITY REFERENCE CHART
Main power window and door lock/unlock switch connector Terminal Front power window motor LH connector Terminal Continuity D7 2 D9 6 Yes Is the inspection result normal?
YES: Replace main power window and door lock/unlock switch. Refer to "REMOVAL AND INSTALLATION ".
NO: Repair or replace harness.
- CHECK HARNESS CONTINUITY 3
- Disconnect main power window and door lock/unlock switch.
- Check continuity between main power window and door lock/unlock switch connector and front power window motor LH connector.TERMINAL CONTINUITY REFERENCE CHART
Main power window and door lock/unlock switch connector Terminal Front power window motor LH connector Terminal Continuity D7 (A) 9 D9 (B) 5 Yes 13 3 - Check continuity between main power window and door lock/unlock switch connector and ground.TERMINAL CONTINUITY REFERENCE CHART
Main power window and door lock/unlock switch connector Terminal Ground Continuity D7 (A) 9 No 13 Is the inspection result normal?
YES: Replace front power window motor LH. Refer to "REMOVAL AND INSTALLATION ".
NO: Repair or replace harness.