Diagnosis Procedure

WARNING: This page is about a different car, the 2011 Nissan Armada. However, it is still accessible from the selected car via links, so may be relevant.

Regarding Wiring Diagram information, refer to "WIRING DIAGRAM - INTELLIGENT KEY SYSTEM/ENGINE START FUNCTION - ".

  1. PERFORM INITIALIZATION

    Perform initialization with CONSULT-III. Re-register all mechanical keys.

    For initialization and registration of mechanical key. Refer to CONSULT-III Operation Manual.

    Can the system be initialized and can steering lock be released with re-registered mechanical key? 

    YES: Steering lock solenoid was unregistered.

    NO: GO TO  2

  2. CHECK STEERING LOCK SOLENOID POWER SUPPLY-1
    1. Turn ignition switch OFF.
    2. Disconnect steering lock solenoid connector.
    3. Check voltage between steering lock solenoid harness connector and ground.
      TERMINAL VOLTAGE REFERENCE CHART

      Terminals Voltage (V) (Approx.)
      (+) (-)
      Steering lock solenoid connector Terminal
      M15 1 Ground Battery voltage
      Fig 1: Checking Voltage Between Steering Lock Solenoid Harness Connector And Ground
      G04916860Courtesy of NISSAN MOTOR CO., U.S.A.

      Is the inspection result normal? 

      YES: GO TO  3

      NO: Repair or replace harness.

  3. CHECK STEERING LOCK SOLENOID GROUND CIRCUIT

    Check continuity between steering lock solenoid harness connector and ground.

    TERMINAL CONTINUITY REFERENCE CHART

    Terminals Continuity
    (+) (-)
    Steering lock solenoid connector Terminal
    M15 4 Ground Yes
    Fig 2: Checking Continuity Between Steering Lock Solenoid Harness Connector And Ground
    G04916861Courtesy of NISSAN MOTOR CO., U.S.A.

    Is the inspection result normal? 

    YES: GO TO  4

    NO: Repair or replace harness.

  4. CHECK STEERING LOCK SOLENOID COMMUNICATION CIRCUITS
    1. Disconnect Intelligent Key unit connector.
    2. Check continuity between steering lock solenoid connector (A) M15 terminals 2, 3 and Intelligent Key unit connector (B) M70 terminals 1, 32.
      TERMINAL CONTINUITY REFERENCE CHART

      Terminals Continuity
      Steering lock solenoid connector Terminal Intelligent Key unit connector Terminal
      M15 2 M70 1 Yes
      3 32
    3. Check continuity between steering lock solenoid connector (A) M15 terminals 2, 3 and ground.
      Fig 3: Checking Continuity Between Steering Lock Solenoid Connector And Intelligent Key Unit Connector M70 Terminals
      G04916865Courtesy of NISSAN MOTOR CO., U.S.A.
      TERMINAL CONTINUITY REFERENCE CHART

      Terminals - - Continuity
      Steering lock solenoid connector Terminals
      M15 2 Ground No
      3

      Is the inspection result normal? 

      YES: GO TO  5

      NO: Repair or replace harness.

  5. CHECK INTELLIGENT KEY UNIT POWER SUPPLY-2
    1. Connect Intelligent Key unit connector.
    2. Check voltage between Intelligent Key unit harness connector and ground.
      TERMINAL VOLTAGE REFERENCE CHART

      Terminals Voltage (V) (Approx.)
      (+) (-)
      Intelligent Key unit connector Terminal
      M70 1 Ground 5
      Fig 4: Checking Voltage Between Intelligent Key Unit Harness Connector And Ground
      G04916862Courtesy of NISSAN MOTOR CO., U.S.A.

      Is the inspection result normal? 

      YES: GO TO  6

      NO: Replace Intelligent Key unit. Refer to "REMOVAL AND INSTALLATION ".

  6. CHECK STEERING LOCK SOLENOID COMMUNICATION CIRCUIT
    1. Connect steering lock solenoid connector.
    2. Using an oscilloscope, check voltage between Intelligent Key unit connector and ground.
      Fig 5: Checking Voltage Between Intelligent Key Unit Connector And Ground
      G04916864G04916790G05382200Courtesy of NISSAN MOTOR CO., U.S.A.NISSAN MOTOR CO., U.S.A.NISSAN MOTOR CO., U.S.A.
      TERMINAL VOLTAGE REFERENCE CHART

      Terminals Condition Voltage (V) (Approx.)
      (+) (-)
      Intelligent Key unit connector Terminal
      M70 32 Ground Steering lock Ignition knob is pushed
      G04916790Courtesy of NISSAN MOTOR CO., U.S.A.
      LOCK status 5
      LOCK <=> UNLOCK
      G05382200Courtesy of NISSAN MOTOR CO., U.S.A.
      For 15 seconds after UNLOCK 5
      15 seconds later UNLOCK 0

      Is the inspection result normal? 

      YES: Replace Steering lock solenoid.

      NO: Replace Intelligent Key unit. Refer to "REMOVAL AND INSTALLATION ".