Diagnosis Procedure
- CHECK GROUND CONNECTION
- Turn ignition switch OFF.
- Check ground connections M16, M70. Refer to
"GROUND INSPECTION
".
Is the inspection result normal?
YES: GO TO 2.
NO: Repair or replace ground connections.
- CHECK CONNECTOR
- Disconnect EVAP control system pressure sensor harness connector.
- Check that water is not inside connectors.
Is the inspection result normal?
YES: GO TO 3.
NO: Repair or replace harness connector.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY CIRCUIT-I
- Turn ignition switch ON.
- Check the voltage between EVAP control system pressure sensor harness connector and ground.CONNECTOR TERMINAL VOLTAGE CHART
EVAP control system pressure sensor Ground Voltage (V) Connector Terminal B172 3 Ground Approx. 5 Courtesy of NISSAN MOTOR CO., U.S.A.
Is the inspection result normal?
YES: GO TO 10.
NO: GO TO 4.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY CIRCUIT-II
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.CONNECTOR TERMINAL CONTINUITY CHART
EVAP control system pressure sensor ECM Continuity Connector Terminal Connector Terminal B172 3 M9 107 Existed Is the inspection result normal?
YES: GO TO 6.
NO: GO TO 5.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors B171, B469
- Harness connectors B418, M66
- Harness for open between ECM and EVAP control system pressure sensor
Repair open circuit.
- CHECK SENSOR POWER SUPPLY CIRCUIT
Check harness for short to power and short to ground, between the following terminals.
ECM SPECIFICATIONSECM Sensor Connector Terminal Name Connector Terminal F105 46 Crankshaft position (CKP) sensor F52 1 F106 64 Camshaft position (CMP) sensor (bank 2) F32 1 Exhaust valve timing (EVT) control position sensor (bank 2) F83 1 Battery current sensor E67 1 M9 103 Accelerator pedal position (APP) sensor E113 5 107 EVAP control system pressure sensor B172 3 111 Refrigerant pressure sensor E66 1 Is the inspection result normal?
YES: GO TO 7.
NO: Repair short to ground or short to power in harness or connectors.
- CHECK COMPONENTS
Check the following.
- CKP sensor (Refer to "COMPONENT INSPECTION ".)
- CMP sensor (bank 2) (Refer to "COMPONENT INSPECTION ".)
- EVT control position sensor (bank 2) (Refer to "COMPONENT INSPECTION ".)
- Battery current sensor (Refer to "COMPONENT INSPECTION ".)
- Refrigerant pressure sensor (Refer to
"MAGNET CLUTCH CIRCUIT
".)
Is the inspection result normal?
YES: GO TO 8.
NO: Replace malfunctioning component.
- CHECK APP SENSOR
Refer to "COMPONENT INSPECTION ".
Is the inspection result normal?
YES: GO TO 15.
NO: GO TO 9.
- REPLACE ACCELERATOR PEDAL ASSEMBLY
- Replace accelerator pedal assembly
- Go to
"SPECIAL REPAIR REQUIREMENT
".
INSPECTION END
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR GROUND CIRCUIT FOR OPEN AND SHORT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.CONNECTOR TERMINAL CONTINUITY CHART
EVAP control system pressure sensor ECM Continuity Connector Terminal Connector Terminal B172 1 M9 112 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES: GO TO 12.
NO: GO TO 11.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors B171, B469
- Harness connectors B418, M66
- Harness for open or short between EVAP control system pressure sensor and ECM
Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
- Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.CONNECTOR TERMINAL CONTINUITY CHART
EVAP control system pressure sensor ECM Continuity Connector Terminal Connector Terminal B172 2 M9 102 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES: GO TO 14.
NO: GO TO 13.
- Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors B171, B469
- Harness connectors B418, M66
- Harness for open or short between EVAP control system pressure sensor and ECM
Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR
Refer to "COMPONENT INSPECTION ".
Is the inspection result normal?
YES: GO TO 15.
NO: Replace EVAP control system pressure sensor.
- CHECK INTERMITTENT INCIDENT
Refer to "DESCRIPTION ".
INSPECTION END