Detailed Flow
- INTERVIEW AND SYMPTOM CONFIRMATION
Check the malfunction symptoms by performing the following items.
- Interview the customer to obtain the malfunction information (conditions and environment when the malfunction occurred).
- Check the symptom.
Is the occurred symptom malfunction?
YES: GO TO 2.
NO: INSPECTION END
- DIAGNOSIS WITH CONSULT-III
- Connect CONSULT-III and perform a self-diagnosis for "MULTI AV".
Refer to "WITHOUT NAVIGATION : CONSULT-III FUNCTION (MULTI AV) ". (without navigation)
Refer to "WITH NAVIGATION : CONSULT-III FUNCTION (MULTI AV) ". (with navigation)
NOTE: Skip to step 4 of the diagnosis procedure if "MULTI AV" is not displayed. - Check if any DTC is displayed in the self-diagnosis results.
Is DTC displayed?
YES: GO TO 3.
NO: GO TO 4.
- Connect CONSULT-III and perform a self-diagnosis for "MULTI AV".
- TROUBLE DIAGNOSIS FOR DTC
- Check the DTC indicated in the self-diagnosis results.
- Perform the relevant diagnosis referring to the DTC Index.
Refer to "WITHOUT NAVIGATION : DTC INDEX ". (without navigation)
Refer to "WITH NAVIGATION : DTC INDEX ". (with navigation)
GO TO 5.
- TROUBLE DIAGNOSIS FOR SYMPTOMS
Perform the relevant diagnosis referring to the diagnosis chart by symptom.
Refer to "WITHOUT NAVIGATION : SYMPTOM TABLE ". (without navigation)
Refer to "WITH NAVIGATION : SYMPTOM TABLE ". (with navigation)
GO TO 5.
- ERROR PART REPAIR
- Repair or replace the identified malfunctioning parts.
- Perform a self-diagnosis for "MULTI AV" with CONSULT-III.NOTE: Erase the stored self-diagnosis results after repairing or replacing the relevant components if any DTC has been indicated in the self-diagnosis results.
- Check that the symptom does not occur.
Does the symptom occur?
YES: GO TO 1.
NO: INSPECTION END