Wiper Dial Position Setting
Front wiper intermittent operation delay interval is determined from a combination of 3 switches (intermittent operation dial position 1, 2, and 3) and vehicle speed signal.
After each intermittent operation delay interval, BCM sends front wiper request signal to IPDM E/R.
WIPER DIAL POSITION SETTING REFERENCE TABLE
| Wiper dial position | Intermittent operation interval | Combination switch | ||
|---|---|---|---|---|
| Intermittent operation dial position 1 | Intermittent operation dial position 2 | Intermittent operation dial position 3 | ||
| 1 | Short โ โ Long |
ON | ON | ON |
| 2 | ON | ON | OFF | |
| 3 | ON | OFF | OFF | |
| 4 | OFF | OFF | OFF | |
| 5 | OFF | OFF | ON | |
| 6 | OFF | ON | ON | |
| 7 | OFF | ON | OFF | |
Example: For wiper dial position 1
Using combination switch reading function, BCM detects ON/OFF status of intermittent operation dial positions 1, 2, and 3.
When combination switch status is as listed below, BCM determines that it is wiper dial position 1.
- Intermittent operation dial position 1: ON (Continuity exists between combination switch output 3 and input 1).
- Intermittent operation dial position 2: ON (Continuity exists between combination switch output 5 and input 1).
- Intermittent operation dial position 3: ON (Continuity exists between combination switch output 4 and input 2).
BCM determines front wiper intermittent operation delay interval from wiper dial position and vehicle speed, and sends wiper request signal (INT) to IPDM E/R.