CONSULT-III Reference Value in Data Monitor Mode
Specification data are reference values.
DATA MONITOR MODE CHART
| MONITOR ITEM | CONDITION | SPECIFICATION | |
|---|---|---|---|
| INT/V TIM (B1) INT/V TIM (B2) |
|
Idle | -5 - 5°CA |
| 2, 000 RPM | Approx. 0 - 20°CA | ||
| INT/V SOL (B1) INT/V SOL (B2) |
|
Idle | 0 - 2% |
| 2, 000 RPM | Approx. 25 - 50% | ||