EXHAUST VALVE TIMING CONTROL LEARNING : Special Repair Requirement
- START
With CONSULT-III
- Start engine and warm it up to normal operating temperature.
- Set selector lever to N position and confirm that following electrical or mechanical loads are not applied.
- Headlamp switch is OFF
- Air conditioner switch is OFF
- Rear defogger switch is OFF
- Steering wheel is in the straight-ahead position, etc.
- Select "EXH V/T CONTROL LEARN" in "WORK SUPPORT" mode with CONSULT-III.
- Touch "START" and wait 20 seconds.
- Keep the engine speed between 2, 200 and 4, 000 RPM.
- Check that "CMPLT" is displayed on CONSULT-III screen.
Learning completed : CMPLT
Learning not yet : YET
Without CONSULT-III
- Disconnect the negative battery terminal and wait at least 10 minutes.
- Reconnect the negative battery terminal.
- Start engine and warm it up to normal operating temperature.
- Set selector lever to N position and confirm that following electrical or mechanical loads are not applied.
- Headlamp switch is OFF
- Air conditioner switch is OFF
- Rear defogger switch is OFF
- Steering wheel is in the straight-ahead position, etc.
- Keep the engine speed between 2, 200 and 4, 000 RPM at 20 seconds.
END