Physical Values
WIRE COLOR REFERENCE CHART
| Terminal No. (Wire color) | Description | Condition | Value (Approx.) | ||||
|---|---|---|---|---|---|---|---|
| + | - | Signal name | Input/Output | ||||
| 1 (G) | Ground | Roof open/close switch (OPEN) | Input | Ignition switch ON | Roof open/close switch (OPEN) | Pressed | 0 V |
| Released | Battery voltage | ||||||
| 2 (BR) | Ground | Roof open/close switch (CLOSE) | Input | Ignition switch ON | Roof open/close switch (CLOSE) | Pressed | 0 V |
| Released | Battery voltage | ||||||
| 3 (B) | Ground | Flipper door limit switch ground | - | Ignition switch ON | - | 0 V | |
| 4 (L) | Ground | Tonneau board switch | Input | Ignition switch ON | Tonneau board | Hooked | Battery voltage |
| Released | 0 V | ||||||
| 5 (SB) | Ground | Trunk room lamp switch | Input | Ignition switch ON | Trunk lid | Locked | |
| Other than above | 0 V | ||||||
| 6 (L) | Ground | Roof latch limit switch | Input | Ignition switch ON | Roof | Close | 0 V |
| Other than above | Battery voltage | ||||||
| 7 (W) | Ground | Flipper door limit switch (UP) | Input | Ignition switch ON | Flipper door LH and RH | Top | 0 V |
| Other than above | Battery voltage | ||||||
| 8 (G) | Ground | Flipper door limit switch (DOWN) | Input | Ignition switch ON | Flipper door LH and RH | Bottom | 0 V |
| Other than above | Battery voltage | ||||||
| 11 (W) | Ground | RAP signal | Input | Ignition switch ON | RAP function | Active | Battery voltage |
| Inactive | 0 V | ||||||
| 12 (Y) | Ground | Back up lamp signal | Input | Ignition switch ON | Shift position | R position | Battery voltage |
| Other than above | 0 V | ||||||
| 13 (BG) | Ground | Sensor power supply | Output | Ignition switch OFF | - | 5 V | |
| 14 (P) | Ground | Trunk link sensor (LH) | Input | Ignition switch ON | Trunk link lock (LH) | LOCK | 0.3 V |
| Other than above | 1.5 V | ||||||
| 15 (SB) | Ground | Trunk link sensor (RH) | Input | Ignition switch ON | Trunk link lock (RH) | LOCK | 0.3 V |
| Other than above | 1.5 V | ||||||
| 16 (GR) | Ground | Roof latch status sensor | Input | Ignition switch ON | Roof latch | Operate | |
| Stop | 0.5 or 4.5 V | ||||||
| 17 (G) | Ground | Roof latch lock sensor | Input | Ignition switch ON | Roof latch | LOCK | 1.0 V |
| Other than above | 3.8 V | ||||||
| 18 (LG) | Ground | Trunk status sensor | Input | Ignition switch ON | Trunk lid (front) | Fully open | 1.0 V |
| Other than above | 3.8 V | ||||||
| 22 (V) | Ground | Roof status sensor power supply | Output | Ignition switch ON | - | 5 V | |
| 23 (B) | Ground | Roof status sensor ground | - | Ignition switch ON | - | 0 V | |
| 24 (GR) | Ground | Parcel shelf status sensor (DRAW) | Input | Ignition switch ON | Parcel shelf motor (DRAW) | Active | |
| Inactive | 0.5 V or 5 V | ||||||
| 25 (R) | Ground | Parcel shelf status sensor (ROTATION) | Input | Ignition switch ON | Parcel shelf motor (ROTATE) | Active | |
| Inactive | 0.5 V or 5 V | ||||||
| 26 (P) | Ground | Roof status sensor signal | Input | Ignition switch ON | Roof | Fully close→Fully open | 0.5 V→5 V |
| 27 (Y) | Ground | Trunk lid open request signal (BCM) | Output | - | Trunk opener | Operate | 0 V →Battery voltage →0 V |
| Other than above | 0 V | ||||||
| 28 (BG) | Ground | Flipper door motor ground | - | Ignition switch ON | - | 0 V | |
| 29 (V) | Ground | Local communication (BCM) | Input/Output | Ignition switch ON | - | ||
| 30 (GR) | Ground | Local communication (POWER WINDOW) | Input/Output | Ignition switch ON | - | ||
| 31 (L) | Ground | CAN-H | Input/Output | - | - | - | |
| 32 (P) | Ground | CAN-L | Input/Output | - | - | - | |
| 33 (V) | Ground | Roof status signal (AUDIO) | Output | Ignition switch ON | Retractable hard top | Fully open | Battery voltage |
| Other than above | 0 V | ||||||
| 35 (B) | Ground | Roof warning buzzer | Output | Ignition switch ON | Roof warning buzzer | Sounds | 0 V |
| Not sounds | Battery voltage | ||||||
| 36 (Y) | Ground | Hydraulic pump relay (RH) | - | Ignition switch ON | Hydraulic pump motor (RH) | Active | 0 V |
| Inactive | Battery voltage | ||||||
| 37 (W) | Ground | Hydraulic pump relay (LH) | - | Ignition switch ON | Hydraulic pump motor (LH) | Active | 0 V |
| Inactive | Battery voltage | ||||||
| 38 (BR) | Ground | Hydraulic pump relay ground | - | Ignition switch ON | - | 0 V | |
| 41 (SB) | Ground | Parcel shelf motor (UP) | Output | Ignition switch ON | Parcel shelf motor (DRAW-UP) | Active | Battery voltage |
| Inactive | 0 V | ||||||
| 42 (W) | Ground | Parcel shelf motor (DOWN) | Output | Ignition switch ON | Parcel shelf motor (DRAW-DOWN) | Active | Battery voltage |
| Inactive | 0 V | ||||||
| 43 (BR) | Ground | Hydraulic pump power supply relay | Output | Ignition switch ON | Retractable hard top system | Active | Battery voltage |
| Inactive | 0 V | ||||||
| 44 (R) | Ground | Parcel shelf motor (HORIZONTAL) | Output | Ignition switch ON | Parcel shelf motor (ROTATION-HORIZONTAL) | Active | Battery voltage |
| Inactive | 0 V | ||||||
| 45 (BR) | Ground | Parcel shelf motor (VERTICAL) | Output | Ignition switch ON | Parcel shelf motor (ROTATION-VERTICAL) | Active | Battery voltage |
| Inactive | 0 V | ||||||
| 46 (G) | Ground | Flipper door motor (UP) | Output | Ignition switch ON | Flipper door motor (UP) | Active | Battery voltage |
| Inactive | 0 V | ||||||
| 47 (L) | Ground | Flipper door motor (DOWN) | Output | Ignition switch ON | Flipper door motor (DOWN) | Active | Battery voltage |
| Inactive | 0 V | ||||||
| 48 (R) | Ground | Roof latch motor (OPEN) | Output | Ignition switch ON | Roof latch motor (OPEN) | Active | Battery voltage |
| Inactive | 0 V | ||||||
| 49 (Y) | Ground | Roof latch motor (CLOSE) | Output | Ignition switch ON | Roof latch motor (CLOSE) | Active | Battery voltage |
| Inactive | 0 V | ||||||
| 51 (SB) | Ground | Trunk lid opener actuator | Output | - | Trunk lid opener | Operate | 0 V → Battery voltage → 0 V |
| Stop | 0 V | ||||||
| 52 (V) | Ground | Trunk lid opener actuator ground | - | Ignition switch ON | - | 0 V | |
| 53 (BG) | Ground | Rear power window motor LH (UP) | Output | Ignition switch ON | Rear power window motor LH (UP) | Active | Battery voltage |
| Inactive | 0 V | ||||||
| 54 (LG) | Ground | Rear power window motor LH (DOWN) | Output | Ignition switch ON | Rear power window motor LH (DOWN) | Active | Battery voltage |
| Inactive | 0 V | ||||||
| 55 (GR) | Ground | Rear power window motor RH (UP) | Output | Ignition switch ON | Rear power window motor RH (UP) | Active | Battery voltage |
| Inactive | 0 V | ||||||
| 56 (P) | Ground | Rear power window motor RH (DOWN) | Output | Ignition switch ON | Rear power window motor RH (DOWN) | Active | Battery voltage |
| Inactive | 0 V | ||||||
| 57 (Y) | Ground | Power source (ROOF) | Input | - | - | Battery voltage | |
| 58 (Y) | Ground | Power source (ROOF) | Input | - | - | Battery voltage | |
| 59 (Y) | Ground | Power source (ROOF) | Input | - | - | Battery voltage | |
| 60 (B) | Ground | Ground (ROOF) | - | Ignition switch ON | - | 0 V | |
| 61 (B) | Ground | Ground (ROOF) | - | Ignition switch ON | - | 0 V | |
| 62 (GR) | Ground | Power source (POWER WINDOW) | Input | - | - | Battery voltage | |
| 63 (Y) | Ground | Power source (POWER WINDOW) | Input | - | - | Battery voltage | |
| 64 (B) | Ground | Ground (POWER WINDOW) | - | Ignition switch ON | - | 0 V | |
| 65 (B) | Ground | Ground (POWER WINDOW) | - | Ignition switch ON | - | 0 V | |
| 66 (P) | Ground | Switching valve 1 | Output | Ignition switch ON | Switching valve 1 | Active | Battery voltage |
| Inactive | 0 V | ||||||
| 67 (SB) | Ground | Switching valve 2 | Output | Ignition switch ON | Switching valve 2 | Active | Battery voltage |
| Inactive | 0 V | ||||||
| 68 (L) | Ground | Switching valve ground | - | Ignition switch ON | - | 0 V | |
| 69 (G) | Ground | Power source (REAR WINDOW DEFOGGER) | Input | - | - | Battery voltage | |
| 70 (P) | Ground | Power source (REAR WINDOW DEFOGGER) | Input | - | - | Battery voltage | |
| 71 (BR) | Ground | Rear window defogger power supply | Output | Ignition switch ON | Rear defogger switch ON and roof is fully closed | Battery voltage | |
| 72 (W) | Ground | Rear window defogger power supply | Output | Ignition switch ON | Rear defogger switch ON and roof is fully closed | Battery voltage | |